Parameter configuration table

Project Technical parameters
Unit structure 8 m 4 sets
Supply voltage/rated frequency 380V ± 10% three-phase four-wire system/50Hz
Rated heating capacity ≥ 45kW
Overall dimension 10100 × 2800 × 4250mm
Cigarette indoor size 8000 × 2700 × 4200mm
Smoke load 4000-4500kg
Energy consumption 1600-1750kWh/furnace
Moisture removal method Internal dehumidification, the moisture in the air in the curing room is discharged in the form of condensed water.
Rated dehumidification capacity (ambient temperature 25 ℃, indoor dry bulb temperature 50 ℃, wet bulb temperature 39 ℃) Dehumidification capacity ≥ 42 kg/h
energy efficiency ratio Heating performance coefficient> 3
Condenser, evaporator Fin type, anti-corrosion and passivation treatment
Heat recovery heat exchanger Plate heat exchanger, heat recovery efficiency greater than 50%
Auxiliary heating 12kW
Circulating fan Protection grade IP54 above, insulation grade f above, fan static pressure ≥ 300Pa, with high and low speed adjustment function, air volume ≥ 18000 m/h
Sensor Temperature measurement range 0 ℃ ~ 99.9 ℃, resolution ± 0.1 ℃, measurement accuracy ± 0.5 ℃
Controller Real-time collection of the dry bulb and wet bulb temperature values of the temperature and humidity sensor in the smoke loading room, automatic/manual control of the baking of the circulating fan, heat pump host unit, etc., with the function of receiving instructions from the remote monitoring system. The LCD screen of the integrated control system, the main board of the controller and the transformers, thermistors, chips, capacitors, relays, plug-ins, etc. used in the integrated control system shall be of high reliability and high durability. The service life of the control equipment is more than 6 years. Each baking season controller failure rate ≤ 2%. The control accuracy of dry bulb temperature is ± 0.5 ℃, and the control accuracy of wet bulb temperature is ± 0.5 ℃. Lightning protection measures: GB/T3482-2008/4
Thermal insulation material The thermal insulation material shall be polyurethane composite thermal insulation wallboard with thickness ≥ 50mm. The inner and outer protective layer of thermal insulation material is coated steel plate above 0.375mm.